Symptom
Unit is heating, but is not
producing
humidity
inside
cabinet. 'LO h20' is flashing,
and unit is full of water.

Error Codes

The following error codes may appear on the digital display to
indicate an error in the operating condition of the unit.
LO h20 = Low water probe does not detect water. Refill water
reservoir — refer to instructions in OPERaTION section of this
manual.
E1 = air temperature sensor malfunctioning. Contact
authorized Service agent or Hatco for assistance.
E2 = Humidity sensor malfunctioning. Contact authorized
Service agent or Hatco for assistance.
dE-L = Water reservoir needs deliming. Contact authorized
Service agent or Hatco for assistance.
4" (102 mm) Adjustable Legs
The 4" (102 mm) adjustable legs are used to add additional
height to the unit.
1. Remove the rack from the unit.
2. Secure all glass sides and doors with tape. Lay the unit
down on a side without controls or doors.
3. Remove the four 1" (25 mm) metal screw-type feet.
Bottom
Cover
1" (25 mm)
Metal
Foot
Installation of 4" (102 mm) Legs
Form No. FDWDm-0915
Probable Cause
When using distilled water, no
minerals are being sensed by low
water probe.
Low water protection system is
malfunctioning.
Probes have lime buildup.
4" (102 mm)
Leg
TROUBLEShOOTING GUIDE
Corrective Action
add one teaspoon of salt to the water reservoir.
Contact authorized Service agent or Hatco for
assistance.
Refer to "Removing Lime and mineral Deposits"
procedure in the maINTENaNCE section to remove lime.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please con-
tact the nearest authorized Hatco Service agency or Hatco for
assistance. To locate the nearest Service agency, log onto the
Hatco website at www.hatcocorp.com and click on
Find Service Agent, or contact the hatco Parts and Service
Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
partsandservice@hatcocorp.com
Fax:
800-690-2966 or 414-671-3976

OPTIONS AND ACCESSORIES

4. Screw the 4" (102 mm) legs into
the holes in the middle of each
corner on the bottom cover. after
all the legs are tightened, return
the unit to its upright position. If the
unit is not level or rocks, turn the
adjustable tip of the appropriate
leg to level the unit.