CDVI DGLPTWLC Manuel D'installation page 4

Masquer les pouces Voir aussi pour DGLPTWLC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
DGLPTWLC
Indoor/Outdoor Proximity Card readers - Wiegand
5] CONNECTIONS: CONNECTION TO THE DOOR CONTROLLER (INTBUSW)
DGLPTWLC
8 points terminal blocks:
+
Alimentation 12 V DC
-
0 V
H
Clock
D0
Data 0
D1
Data 1
B
Buzzer
V
Green LED
R
Red LED
Power supply
Two different configurations,
are possible:
12VDC only
(As standard)
Cut the strap
12VAC or 24VDC
cdvi.com
4
cdvigroup.com
DIPSWITCH 1 & 2
POSITIONNING
1 2
3
4
ON
OFF/ON
44 bits
OFF
1 2
3
4
DGLPTWLC
INTBUSW
Strike
Electromagnet
Varistor
DIPSWITCH 3
POSITIONNING
The buzzer and the LED's
can be controlled by the reader
or by an external device.
1 2
3
4
ON
OFF
1 2
3
4
The controller or the audio entry system
can manage the LED and the buzzer to program
other operations.
Door contact (not used)
Connect E and M
EN
OFF
CDVI
Mode
Shielded
cable
To other door
controllers (INTBUSW)

Publicité