Installation of the module
- Insert the module vertically with the large
connector strip at the top in the top and
bottom guide rails of a slot. You can select
freely between slots 1 to 4.
- Push the module carefully back until the
connectors grip and the lug of the module
snaps into the lock.
Closing the housing
Replacing the cover
- First hook in the cover at the top of the hous-
ing. The three latches engage behind the edge
of the housing.
- Press onto the cover until it latches into the
housing at the bottom.
Locking the cover
!
The housing must be locked before plugging in the telephone system's
230 V- mains plug.
Startup
- Switch on the telephone system by plugging
in the 230 V- mains plug.
Figure 4
- Stick the enclosed label showing the module
connections above the module slot on the
housing.
- Please see the operating instructions -
chapter 'Installation' of the telephone system
AS 40 for information about connecting the
module.
Locking the cover
- Insert the bolt with the hook facing down-
wards in the cover opening, turning the bolt
slightly (Fig.4).
- Push the bolt in past the pressure point up to
the stop (fig. 5)