Installation of the AS 40 modules
Safty notes
!
Before unlocking the cover, remove the 230 V mains plug from the
telephone system.
Opening the housing
Unlocking the cover
- Pull out the black bolt slightly to the side
using a narrow srewdriver blade (about 2 mm
wide) until you can grip the bolt (Fig.1 and 2).
- Hold the bolt and pull it right out turning it
slightly (Fig. 2 and 3).
You can use the bolt as a module extractor
when exchanging a module.
Unlocking the cover
Removing the module from the packaging - Safety measure
Before removing the module from the
packaging and before inserting the module in
the AS 40, touch the metal shield of the PC/
printer socket on the bottom of the AS 40
briefly with your finger. This discharges any
4
Fig. 1
Removing the cover
- Grip the underside behind the finned cover
that covers the telephone system's connection
panel.
- Pull the edge of the cover down slightly to
unlatch it. Detach the cover towards you.
Fig. 2
possible electrostatic charge and protects
electrostatically sensitive components of the
AS 40 and the module.
Bolt
Fig. 3