MICROWAVE SENSOR - PARAMETER SETTINGS
Detection Area (Sensitivity)
This determines the eff ective range of the motion detector and is set
with DIP switches on the sensor, please see fi gure below. Note that
reducing the sensitivity will also narrow the detection range.
I
ON
II
III
ON
IV
Daylight Threshold
This allows the sensor to switch the unit on when daylight level is
either full daylight (50Lux), low daylight (10/30Lux), or after dark (2Lux).
It also allows the sensor to be disabled. As long as the light level is
above the set point, the fi xture will stay off when motion is detected.
I
II
III
IV
V
MICROWAVE SENSOR - APPLICATION
0% / 100%
Off with suffi cient ambient light --> in the evening / at night after motion detection 100% during hold time --> then off
1
Off with suffi cient daylight,
even after detection.
8
1
2
ON 100%
-
ON
75%
-
50%
-
-
25%
6
7
8
ON
ON
ON
2Lux
ON
ON
-
10Lux
-
ON
-
30Lux
ON
-
-
50Lux
-
-
-
Disable
2
100% during hold time, upon detection
and insuffi cient daylight.
www.prolumia.com
Hold Time
This determines the time the fi xture remains at 100% and is set with
DIP switches on the sensor, please see fi gure below. The walk test
(5s) setting is useful when installing the fi xture to establish correct
operation and range.
I
II
III
IV
V
VI
3
3
4
5
ON
ON
ON
5s
-
ON
ON
30s
ON
-
ON
90s
-
-
ON
5min
ON
ON
-
20min
-
-
-
30min
Off after hold time.