DO NOT INSTALL SMOKE ALARM DEVICES IN THE FOLLOWING PLACES
1. Near appliances or areas where normal combustion regularly occurs
(kitchens, near furnaces, hot water heaters).
Use specialized smoke alarms with unwanted alarm control for these areas.
2. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines.
Install at least 10 feet away from these areas.
3. Near air conditioners or heating and cooling supply vents.
Install at least 3 feet away from these areas.
The air could blow smoke away from the detector, interrupting the alarm.
4. In rooms where temperatures may fall below 0°C or rise above 40°C.
5. In extremely dusty, dirty, or insect – infested areas; particles interfere with the smoke alarm
operation.
BATTERY SPECIFICATION
Rating voltage:
Package:
Recommend battery: Energize: E91
REPLACE BATTERY
1. Turn the alarm body counterclockwise and take out the alarm body from the bracket.
2. Take out the old battery from the battery box.
3. Fix the two new batteries to the battery box. Please note the battery polarity.
4. Fix the battery into battery box, fit alarm body on bracket and turn the alarm body clockwise.
5. Test smoke alarm using test button.
The sound pattern is 3 short beeps-1.5seconds pause, and repeats.
If there's no sound output, it means that the smoke alarm is faulty or the installing operation
is wrong, please follow the instructions in "TROUBLE SHOOTING".
NOTE
During testing, the other smoke detector will send an alarm because the unit is
sending a wireless signal.
Once you release the test button, the other smoke detector will stop alarming after
1 minute.
DC 1.5V
AA alkaline battery
Gold Peak Group: GP 15A LR6