Current Limitation; Specifications - Goobay DF 1730 LCD Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating as a constant current source:
1. Turn on the power supply unit with separated, or switched off power by
mains switch 6.
2. Turn the voltage regulator (fine adjust 10 and coarse adjust 11) fully
clockwise completely on.
3. Turn current regulators 4 and 5 counterclockwise completely off.
4. Connect the load, or turn it on.
5. Use the regulators 4 and 5 to adjust the current.
The constant current display (CC ) shines.
Operating as a constant voltage source:
1. Turn on the power supply unit with separated, or switched off power by
mains switch 6.
2. Turn the current regulator 4 and 5 clockwise fully on.
3. Turn the voltage regulator 10 and 11 in the counterclockwise direction
fully off.
4. Connect the appropriate variable load, or turn it on.
3. Use the voltage regulators 10 and 11 for adjusting the voltage.
The constant voltage display (CV) shines.

Current limitation:

When used as a constant voltage source, the output current control is set to maximum in
general. The current may be further limited for specific applications by the corresponding
channel is shorted and the current limit value is set.

9 Specifications:

model
input voltage AC
output voltage DC
output current
accuracy
regulation of the load
20325
20319
230V ±10% / 50Hz ±10%
230V ±10% / 50Hz ±10%
0-30V stufenlos
0-30V stufenlos
0-3A stufenlos
0-3A stufenlos
CV 1x10
+ 500mV
CV 1x10
-4
CC 5x10
+ 1mA
CC 2x10
-3
CV < 10mV
CV < 1x10
CC < 5x10
+ 10mA
CC < 2x10
-3
20327
230V ±10% / 50Hz ±10%
0-30V stufenlos
0-10A stufenlos
+ 1mV
CV 1x10
-4
+ 1mA
CC 5x10
-3
+ 2mV
(for I<6A) CV < 2x10
-4
+ 2mA
CC < 5x10
-3
(for I>6A) CV < 5x10
+ 10mV
-4
+ 10mA
-3
+ 10mV
-4
+ 10mA
-3
+ 10mV
-3
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Df 17132 sb-3a ledDf 3010203252031920327

Table des Matières