INFOSEC UPS SYSTEM X3 EX-500 Notice D'utilisation page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Caution: The telephone line lightning arrester could be rendered inoperable if improperly
installed. This surge protection device is for indoor use only. Never install telephone wiring
during a lightning storm.
Note: This connection is optional.
8 . C O M P U T E R I N T E R F A C E
To prevent an abrupt computer system shutdown, connect a USB cable to your computer.
Then you can install and use the automatic shutdown software (Free download from web
site).
The USB communication port at the back of the UPS enables the computer to directly
control UPS status.
The main functions are as follows:
- Transmission of a visual alarm in event of power failure
- Automatic file closure prior to the battery going flat
- Computer & UPS shutdown
For more information, go to the website: www.infosec-ups.com
9 . B A T T E R Y
The battery is the only UPS component which is not in permanent use. It has a useful life of
approximately 3 to 5 years. However, frequent major discharges or exposure to temperatures
over 20C will shorten its life span. We therefore recommend that users recharge the battery
once every 3 months when the unit is not in use in order to compensate for natural discharging.
UPS backup time will depend on the powered load, as well as the age and condition of the
batteries.
WARNING!
Batteries should always be replaced by qualified technicians. Batteries have a very high
short circuit current: connection errors could cause electric arcs resulting in serious
burns.
1 0 . T R O U B L E S H O O T I N G
Should the UPS fail to function correctly we recommend you perform the following tests before
calling the Hot Line.
Check list:
• Is the main switch in the "ON" position?
• Is the UPS plugged into the mains power supply?
• Does the power supply fall within specified unit values?
• Has the fuse gone in the mains plug?
• Is the UPS overloaded?
• Is the battery flat or defective?
PROBLEM
No words display on
front panel.
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 10 20 AA 59 205 12
POSSIBLE CAUSE
Low battery.
Faulty battery.
UPS is not turned on.
SOLUTIONS
Charge battery for up to 6 hours.
Replace with the same type of battery.
9

Publicité

Table des Matières
loading

Table des Matières