Instructions for using the Hydraulic Flow Meter
1. Open loading valve by rotating counter-clockwise.
2. Start pump momentarily to ensure oil flows freely through the hydraulic system, then run
pump at maximum speed. Do not change pump speed while turning the loading valve.
3. Slowly close the loading valve to develop the desired pressure. Run the machine until
normal operating temperature is reached i.e. typically 115 - 140°F (45 - 60°C).
4. Open the loading valve to read the flow at minimum pressure.
5. Close loading valve slowly to increase pressure. Note reduction of flow as the pressure is
increased to maximum pump pressure to determine pump condition.
Pump
Pump
Typical Tests
Pump Test
Cylinder
Tank