Press button A once: Measure the area height
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the first area
length
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the second
area length
→ The result is displayed at the bottom in m²
6.7.5 "Add/subtract results" (Fig. 9)
Procedure:
Important!
Results can be added and subtracted in the dis-
tance, area and volume functions.
Press button A once:
Switch on the equipment
Press buttons C + A: Call up the menu and
select a function (see 6.4)
(distance, area, volume)
Measure results (as described above)
Press button D (+) once: Add the new measu-
rement
Press button F (-) once: Subtract the new
measurement
→ The result is displayed at the bottom in m
6.7.6 Function: "Staking out function"
(min. 10 cm = 0.1 m)
Symbol
(Fig. 10)
Procedure:
Press button A once: Switch on the equip-
ment
Press button B if necessary (approx. 1 se-
cond): Switch on the sound if it is switched off
(see 6.3)
Press buttons C + A: Call up the menu and
select a function (see 6.4)
Press button G if necessary: Select the refe-
rence point on the equipment (see 6.6)
Button D (+): Increase the preset value (1.000
m)
Button F (-): Reduce the preset value (1.000
m)
Press button A once: Measurement
Move the equipment backwards away from
the 0 point
→ Continuous measurement: The faster the
beep signal becomes, the closer you are to
the desired distance.
Anl_TE_LD_60_SPK9.indb 23
Anl_TE_LD_60_SPK9.indb 23
GB
6.7.7 Function: "Indirect distance measure-
ment 1" (Adjacent side (b) using the Pytha-
goras rule)
„Symbol
" (Fig. 11)
Procedure:
Press button A: Switch on the equipment
Press buttons C + A: Call up the menu and
select a function and subfunction (see 6.4)
Press button G if necessary: Select the refe-
rence point on the equipment (see 6.6)
Caution!
The desired length, in this case the adjacent
side (b), and the opposite side (a) must be at
right-angles to each other (see Fig. 11).
Important!
Only the hypotenuse (c) is measured. The
angle between lengths (c) and (b) is auto-
matically measured in the background. The
value which is then displayed is the resultant
calculated adjacent side (b).
Press button A once: Switch on the laser
Align the laser
Press button A once: Measure the hypotenu-
se (c)
→ The length of the adjacent side (b) is dis-
played at the bottom in m
6.7.8 Function: "Indirect distance measure-
ment 2" (Opposite side (a) using the Pytha-
goras rule)
Symbol
(Fig. 12)
Procedure:
Press button A: Switch on the equipment
Press buttons C + A: Call up the menu and
select a function and subfunction (see 6.4)
Press button G if necessary: Select the refe-
rence point on the equipment (see 6.6)
Caution!
The desired length, in this case the opposite
side (a), and the adjacent side (b) must be at
right-angles to each other (see Fig. 12).
Important!
Only the hypotenuse (c) is measured. The
angle between lengths (c) and (b) is auto-
matically measured in the background. The
value which is then displayed is the resultant
calculated opposite side (a).
- 23 -
21.12.2017 13:22:59
21.12.2017 13:22:59

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

22.700.85

Table des Matières