10.4 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by a qualified electrician.
Important! The carbon brushes should not be re
placed by anyone but a qualified electrician.
10.5 Transport (fig. 1)
The compressor can be transported by tilting to the
wheels.
10.6 Ordering replacement parts
Please quote the following data when ordering
replacement parts:
• Type of machine
• Article number of the machine
12. Troubleshooting
Fault
Possible cause
The compressor does
• No supply voltage.
not start.
• Insufficient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
The compressor starts
• The nonreturn valve leaks.
but there is no pres
sure.
• The seals are damaged.
• The drain plug for condensation water (1)
leaks.
The compressor
• The hose connections have a leak.
starts, pressure is
shown on the pressure
• A quicklock coupling has a leak.
gauge, but the tools
do not start.
• Insufficient pressure set on the pressure
regulator (7).
11. Disposal and recycling
The unit is supplied in packaging to prevent its
being damaged in transit. This packaging is raw
material and can therefore be reused or can be re
turned to the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic. Defec
tive components must be disposed of as special
waste. Ask your dealer or your local council.
Remedy
• Check the supply voltage, the power plug and
the socketoutlet.
• Make sure that the extension cable is not
too long. Use an extension cable with large
enough wires.
• Never operate with an outside temperature of
below +5° C.
• Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
• Have a service center replace the nonreturn
valve.
• Check the seals and have any damaged seals
replaced by a service center.
• Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
• Check the compressed air hose and tools and
replace if necessary.
• Check the quicklock coupling and replace if
necessary.
• Increase the set pressure with the pressure
regulator.
GB
27