19
5.1. Disconnect the nailer from the air supply.
5.2. Remove the slotted screw or Allen head screw from the oil port hole on the right side of the
tool that has "OIL" stamped.
5.3. Put three teaspoons of air tool oil in the oil port hole. Replace the screw.
5.4. Reconnect the air supply to the nailer and run for 20 to 30 seconds. Lubricate the entire tool
mechanism by rotating the tool upside down and sideways while running the tool.
5.5. Remove the screw and hold the oil port hole over a suitable container to allow excess oil to
drain.
5.6. If the oil is dirty, repeat the procedure until the oil comes out clear. Install the screw and
tighten. The residual oil remaining in the nailer mechanism chamber is all that is needed for proper
lubrication.
ENGLISH