Operation With Residual Humidity Control (Optional) - Domus DTA-11 Manuel D'utilisation

Masquer les pouces Voir aussi pour DTA-11:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. OPERATION WITH RESIDUAL HUMIDITY CONTROL
(OPTIONAL)
The humidity control is a system that automatically adjust the drying time for each tissue type and
load, ensuring optimum performance at the level of consumption and time.
The humidity sensor monitors the relative humidity value and reached the set point determined by
the user, the microprocessor stops the drying stage and proceeds to the cooldown, to gradually cool
clothes.
Microprocessor default programs have established the relative humidity values by default, see table
in Chapter 6.
To modify the values of relative humidity indicated in the default programs click on "SELECT" and
increase or decrease by using the arrow keys.
Relative humidity levels in which we will consider that the clothes are dry between 20 - 35%
RH Depending on various parameters. We recommend the user to determine the most optimum
moisture level in their applications.
Página 54 de 109
DTA-DTP-11-18-27_Manual_ML

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dta-18Dta-27Dtp-11Dtp-18Dtp-27

Table des Matières