REK31E
Parameter
d1
Main Set point
d2
Differential ( hysteresis )
d3
lower limit of main set point
d4
Upper limit of main set point
d5
Minimum time interval between the disactivation and successive activation on compressor
d6
Max temperature alarm differential
d7
Maximum or minimum temperature alarm delay
d8
Time interval between defrost cycle
d9
Max defrost cycle time
d12
Real temperature display delay at defrost end
d14
Dripping time
d19
Offset ?
d22
Unit of measure, 0=C, 1=F
d23
Compressor function during o probe failure
d24
Compressor on-time during probe failure
d25
Compressor off-time during by probe failure
d38
Minimum temperature alarm differential
Description
REK31
2 ºC
3 ºC
2 ºC
10 ºC
99sec.
50 ºC
0
6h
20min
30 min
1min
-4 ºC
0
2
10 min
10 min
40 ºC
47