Anleitung SE 5500 SPK 1a
GB
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection (4) on the gene-
rator and an external earth point.
10. Maintenance
Remove dust and dirt from the machine at regular
intervals. The best tools for cleaning are a fine
brush or a cloth
Do not use any caustic substances to clean the
plastic
Take the petrol out of the generator if you
do not intend to use the generator for a lengthy
period of time
Important: Switch off the machine immediately
and contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or misfires
11. TECHNICAL DATA
Generator
Synchronous
Protection type:
Continuous power S1:
Maximum power S2 5 min.:
Rated voltage:
3x230 V
/ 1x400 V 3
Rated current:
Frequency:
Drive engine design
4-stroke, air-cooled
Displacement
Max. power:
9,55 kW / 13 PS
Fuel:
normal unleaded petrol
Tank capacity:
Weight:
LWA sound power level:
Sound pressure level LWM:
Spark plug:
NGK BPR5ES
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output (5 min). Afterwards the machine
10
19.04.2005
12:55 Uhr
Seite 10
must be stopped for a while to prevent it from
overheating (5 min).
12. Changing the oil and checking the
oil level (before using the machine)
The engine oil is best changed when the engine is at
working temperature.
Only use engine oil (15W40).
Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine oil
drain out into a drip tray.
After the old oil has drained out, close the oil drain
plug and place the generator on a level surface
again
Fill in engine oil up to the top mark on the oil dip
stick (approx. 1.1 liters).
Important: Do not screw in the oil dip stick – only
insert it.
Dispose of the old oil properly.
13. Cleaning the air filter
IP 23
Remove the cover from the air filter.
4800 W
Now you can remove the filter elements.
Do not use abrasive cleaning agents or petrol to
5500 W
clean the elements.
Clean the elements by tapping on a flat surface.
6,95 A
50 Hz
389 cm
3
25,0 l
93 kg
98 dB(A)
96 dB(A)