2.2
Technical Data
Type
Description
AKI0
1 Zone Table top
BKI0
1 Zone Built in
AWI1
Wok Table top
BWI1
Wok Built in
AKI1
2 Zones Table top
BKI1
2 Zones Built in
AKI0
1 Zone Table top
BKI0
1 Zone Built in
AWI1
Wok Table top
BWI1
Wok Built in
AKI1
2 Zones Table top
BKI1
2 Zones Built in
Operating conditions
Max. tolerance of
the nominal supply
voltage
Supply frequency
Protection class
Minimal diameter
of the pan
3.
Installation
3.1
Requirements of installation
Place the induction unit on to a flat surface.
Do not disturb the air flow in- and outlets.
The table must be able to carry min. 40 kg.
The switch must be easy accessible.
Installation ambience
Max. ambient temperature
Storage
Function
Max. relative humidity of air
Storage
Function
3.2
Installation instructions
Please observe the following rules:
- Check and ensure that the supply voltage matches the
voltage given on the specification plate
- The electrical connections must satisfy local house
installation regulations. The valid, national and local
regulations of the electricity-supply inspection
authorities must be observed.
- This induction appliance is equipped with a mains
cable which can be connected with the necessary plug
to the socket. The connector must be easily accessible
to disconnect the unit from the net.
- When faulty-current circuit breakers are used, they
must be rated for a breaking current of 30mA or more.
- This induction unit is equipped with an internal air
cooling system. Make sure that the air supply and air
exhaust are not blocked (wall, fabric etc)
Electrical connection
230V AC 1NPE 50/60Hz
230V AC 1NPE 50/60Hz
230V AC 1NPE 50/60Hz
230V AC 1NPE 50/60Hz
400V AC 3PE
400V AC 3PE
400V AC 3PE
400V AC 3PE
400V AC 3PE
50/60Hz
400V AC 3PE
400V AC 3PE
400V AC 3PE
Nominal tension:
+6% / -10%
50 / 60 Hz
IPX2
12 cm
> -20°C to +70°C
> + 5°C to +40°C
> 10% to 90%
> 30% to 90%
Power
Fuse
3.5 kW
16A
3.5 kW
16A
3.5 kW
16A
3.5 kW
16A
50/60Hz
7.0 kW
16A
50/60Hz
7.0 kW
16A
50/60Hz
5.0 kW
10A
50/60Hz
5.0 kW
10A
5.0 kW
10A
50/60Hz
5.0 kW
10A
50/60Hz
10.0 kW
16A
50/60Hz
10.0 kW
16A
- The induction unit is disposing of a removable fat filter.
Prevent hot- or unctuous air to be sucked into the unit.
- Do not set an unit on a hot surface or beside a heat
absorbing device.
- The air intake temperature must be under 40°C
- The operating staff has to make sure that installation,
support and inspection is done by qualified personnel.
3.3
Aufstellung Tischmodelle AKI0, AKI1, AWI1
Min. wall clearance 4,0 cm
When installing in a niche, consider to
carry away the outgoing air by means of slots
upwards, or lateraly under the cover.
Under no circumstances operate the unit
without sufficient air discharge!
Several units can be screwed
flush together by means of screws
1 and 2.
20
Cable
Weight
H07RN-F 3G1.5
19.3 kg
H07RN-F 3G1.5
15.8 kg
H07RN-F 3G1.5
20.1 kg
H07RN-F 3G1.5
16.6 kg
H07RN-F 4G2.5
25.5 kg
H07RN-F 4G2.5
22.0 kg
H07RN-F 4G1.5
20.3 kg
H07RN-F 4G1.5
16.8 kg
H07RN-F 4G1.5
21.1 kg
H07RN-F 4G1.5
17.6 kg
H07RN-F 4G2.5
27.0 kg
H07RN-F 4G2.5
23.5 kg
615
22
1
2