8
1
Mounting and load application
The load cells are firmly clamped at the mounting holes, the load is applied at
the other end. The scope of supply includes 2 gaskets for sealing the
mounting surfaces against microbiological contamination. The recommended
screws and tightening torques can be found in the table below:
Version
Thread
Standard
Rustless
*)
Recommended value for the specified property class. Please comply with the screw manufacturer's
instructions with regard to screw dimensions.
Load must not be applied to the side where the cable connection is located,
as this would cause a force shunt.
Load application / platform center
O-ring seal
2
Electrical connection
The following can be connected for measurement signal conditioning:
S carrier-frequency amplifier
S DC amplifier
designed for strain gage measurement systems.
HBM
Max. thread reach
M6
14 mm
M6
14 mm
É É É É É É É É É É
É É É É É É É É É
É É É É É É É É É É
É É É É É É É É É
Platform Scales PW27...
Min. property class
8.8
A2−70 or A4−70
O-ring seal
Tightening
*)
torque
10 N⋅m
10 N⋅m
A3010−1.0 en/de/fr