4. Programming the individual dosing pumps
Every one of the four dosing pumps can be controlled separately.
Note: the dosing volume of 1,000 ml for each dosing unit should not be exceeded because this significantly reduces the
pump's service life. Having delivered the maximum volume of 1,000 ml a delay of at least 30 min should be maintained before
the next dosing unit.
· minimum flow rate of 1 ml can be set
· recommended max. flow rate 9,999 ml/day
· adjustable dosing time
· 1 – 24 dosing units/day can be set
· Interval days 0 – 30 can be set
· Output: approx. 60 ml/min
Press the Menu button to access the programming level.
Set
Date & Time
Set
Program <
The < symbol indicates which programming level you have currently selected. Use the  or  button to navigate between the
programming levels. Confirm Set Program by pressing the Menu button.
Select Pump-set:
1 2 3 4
You can now use the  and  buttons to select the pump to be programmed.
By pressing the Menu button again you confirm the selected pump and can use the  or  button to set the desired number of
dosing units per day (1 – 24).
P1 Time Per Day:
For: 01 (1 – 24)
P1 represents pump 1 to be programmed, P2 pump 2 etc.
By pressing the Menu button you set the interval days.
P1 Interval Day:
For: 00 (0 – 30)
The  and  buttons are used to enter the number of day intervals. With a day interval of 01, a dose will be dispensed ever day,
with 02 every two days etc. The setting 00 defines a daily dose as of today.
Then you can press the Menu button to set the dosing volume.
P1 Dosing Volume:
Num: 01 -- : 0010ml
Use the  and  buttons as well as the  and  buttons to set the desired dosing volume.
By pressing the Menu button you can use the  and  buttons as well as the  and  buttons to set the dosing times.
Dosing Time:
Num: 01 -- : 12:00
If several dosing units are desired, press the Menu button again and use the  and  buttons as well as the  and  buttons to
define more dosing volumes and dosing times.
P1 Dosing Volume:
Num: 02 -- : 0010ml
P1 Dosing Time:
Num: 02 -- : 13:00
7