Operating temperature
Humidity
CE conformity
Type test
Dimensions
(W x H x D)
Protection level
230 V model:
Operating voltage:
Power consumption:
Weight:
Protection class
12 V model:
Operating voltage:
Current consumption:
Weight:
Protection class

Safety information

!
Operate the gas alarm only with the operating
voltage specified for the device. The 12 V model
must be powered only by a 12 V DC (SELV) supply.
!
Do not leave small children unsupervised with the
appliance, batteries, packing material or small
parts. Otherwise there is a risk of fatal injury due to
choking.
!
Do not damage any cables or pipes for gas,
electricity, water or telecoms when you are drilling
or mounting the device! Otherwise there is a risk to
life and limb!
!
This device is only suitable for indoor use. Keep
away from moisture.
!
Modifications made to the gas alarm can result in
(±10%), max. 200 mA
automatic if gas
concentrations fall below
the alarm threshold
-10°C to +40°C
max. 95% rel.
EN 61000-6-3:2007
EN 50270:2006
EN 50194-1:2009
140 x 125 x 42 mm
IPX2D
230 V AC / 50 Hz
max. 6 VA
approx. 500 g
II
12 V DC
(-15% / +20%)
max. 130 mA
approx. 250 g
III
electric shock or malfunction.
!
If the mains power cable of this device is damaged,
it must be replaced by the manufacturer or his
customer service department or a similarly qualified
person in order to avoid hazards.
Placement
The gas alarm is designed to be wall-mounted.
The installation location must be selected in
accordance with the following criteria:
For liquefied gas (propane/butane)
For the detection of liquefied gas, the distance from
the floor should be 15 - 30 cm and the distance to the
gas device at most 4 m. Please make sure that the
selected installation site is not directly next to an exit.
Escaping liquefied gas is heavier than air so falls to
the floor and spreads out there.
For town gas/natural gas (methane)
For the detection of town gas/natural gas, the gas
alarm should be installed 15 - 30 cm below the
ceiling and at most 6 m from the gas device. Please
make sure that the selected installation site is above
the highest window or door opening. Town gas and
natural gas are lighter than air so rise upwards.
The following locations are NOT suitable
installation sites:
!
Outside of buildings, e.g. for the monitoring of open
bottle crates
!
Separated areas (e.g. closet interiors or behind
curtains) which could, in the event of a gas leak,
prevent the alarm from triggering
!
In air currents from fans (ventilation, air-
conditioning, etc.) or in the vicinity of doors or
windows
!
Close to a extractor vent or hood
!
Areas in which the temperature can fall below -