8. CHARGE STATE INDICATION
LED 25%
LED 50%
Blinking
OFF
ON
Blinking
ON
ON
ON
ON
ON
ON
REMARK
1. If, during the trickle charge, the voltage goes over 15V +/- 0.25V in 12V mode or over 7.5V +/- 0.25V
in 6V mode, the charger will interrupt the delivery of charging current. When the voltage will drop to
12.8V or 6.4V +/- 0.25V, the charger will start again charging but without the charge state lights.
2. When the charger is plugged to the mains supply, all LEDs light up for approx. 0.5 seconds, then it
configures itself in standby mode or goes to the last selected mode unless, within 5 seconds, the
user selects a different charge mode by pressing the MODE button.
9. BULK CHARGING TIME
To charge to approx. 80% of capacity (hours)
Battery (Ah)
2.2
7.2
14
25
30
40
LED 75%
OFF
OFF
Blinking
ON
ON
6V
1.5
5
8.5
-
-
-
11
LED 100%
CHARGE STATE
OFF
Below 25%
OFF
Below 50%
OFF
Below 75%
Blinking
Below 100%
ON
Fully charged
To charge to approx. 80% of capacity (hours)
12V
1.5
8.5
15.5
24.5
5
18