Servicing
11
Servicing
Work on the ammeters may only be carried out by appropriately authorized and trained
personnel.
Before any work commences, the ammeters must be disconnected from the supply.
The ammeters must not be opened. They can only be repaired by the manufacturer!
Observe the relevant national regulations in the country of use!
11.1 Maintenance
The following points must be checked during maintenance:
• clamping screw holding the cable is securely seated.
• plastic enclosures for formation of cracks.
• compliance with permitted temperatures (to EN 50014).
11.2 Accessories and spare parts
Use only original accessories and spare parts made by R. STAHL Schaltgeräte GmbH.
Use of another company's accessories and spare parts invalidates the device and acces-
sory warranty of R. STAHL Schaltgeräte GmbH.
Accessory
Type 8040
Type 8603/1 Bezel for type 8405
Type 8603/2 Bezel for type 8403
Scale plates will be supplied on request
Table 11-1: Accessories
12
Transport and storage
• Transport and storage are only permitted in the original packing.
13
Disposal
Observe the national standards for refuse disposal.
12
Ammeter Version 8403/2 and 8405/2
Description
Fixing plate for snap-on fixing type 8405
Order number
80 408 05 29 0
88 000 07 40 7
88 000 01 45 7