Care And Cleaning; Disposal; Technical Data - VOLTCRAFT 511568 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. Care and cleaning

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause
damage to the housing and malfunctioning.
• Disconnect the product from the mains before each cleaning.
• The switched-mode mains power supply units are maintenance-free, apart from the need to replace fuses and
cleaning them once in a while. Use a clean, lint-free, antistatic and dry cloth to clean the device.

11. Disposal

Product
1
Electronic devices are recyclable waste and must not be disposed of in the household waste. At the end of
its service life, dispose of the product in accordance with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

12. Technical data

Operating voltage
Power consumption
Output 3-15 V/DC voltage
Output current
Residual ripple
Control response at Change
of mains supply +/- 10%:
Change of load 0~100%:
Mains fuse
Operating temperature
Rel. humidity
Dimensions (W x H x D)
Weight
SPS 1525 PFC
230 V~ / 50 Hz
max. 460 VA
(variable) or fixed voltage of 13.8 V
25 A
10 mVrms (rms=effective)
80 mV
230 mV
3.15 A / 250 V
(fast blowing)
+ 0 °C to + 40 °C
max. 85 (non-condensing)
220 x 110 x 240 mm
approx. 2.6 kg
SPS 1540 PFC
max. 782 VA
40 A
5 A /250 V
(fast blowing)
220 x 110 x 310 mm
approx. 3.5 kg
SPS 1560 PFC
max. 1058 VA
1 -15 V/DC controllable
5 A front; 60 A rear
max. 40 mVp-p
0.05%+ 3mV
0.1% + 5mV
220 x 110 x 360 mm
approx. 5.8 kg