L
• For suction heights exceeding 3 m we recommend securing the suction-hose (e.g. by fastening it to a
wooden post). This relieves the pump of the weight of the suction hose.
• Install the intake and discharge lines in such a way that they do not place the pump under any
U
mechanical strain.
Priming the pump
Z
First, unscrew the filling plug to remove air from the pump during filling.
Fill the pump with clear water via discharge connector. Filling must be done slowly so that the air
contained in the pump is completely expelled. Fill to overflow and put back the filling plug. As this is
A
not an auto-priming pump, the suction pipe will also need to be filled. To save time when filling, you
can detach the suction pipe set and fill it directly (by submerging the suction pipe in water, for example)
before connecting the pump.
O
Depending on the suction height and the amount of air in the suction hose, priming can take anywhere
between 1 minute to 5 minutes. If it takes longer than this, the pump should be refilled with water.
N
Illustration 11
Always remove the plug from the socket before refilling !
Connecting the discharge hose
A hose with a diameter of 25MM is recommended for better results.
4.4 OPERATION
Start the pump
Make sure the pump is correctly installed and primed, refer to chapter "first use" above.
Connect the power cable to an earthed 230V 50Hz power supply protected by a minimum 10-amp
fuse. Press the ON/OFF switch. The switch light will come on when the motor is running. Once the pump
has been primed, put the discharge hose back down.
Operation safety warnings
• Operate the product only at reasonable hours – not early in the
morning or late at night when people might be disturbed.
• Do not modify the product in any way or use parts and
accessories that are not recommended by the manufacturer.
Operate the pump
• In order to prevent dry-running and overheating of the machine, always make sure that the suction
hose is immersed under water.
• The motor is protected against overheating by an integrated thermostat. In the event of overheating,
the thermostat will automatically switch o the pump. The pump will automatically restart after it has
cooled down.
Stop the pump
• To reduce the risk of injury, always stop the machine :
- before cleaning or clearing a blockage
- before installing or removing attachments
- before checking, maintaining or working on the product
illustration 4 to 6
illustration 8
illustration 9 to 11
to vibrate abnormally, immediately stop the product and
inspect for damage or identify the cause of the vibration.
Any damage should be properly repaired or replace by an
authorized service center.
14
193
FR
ES
PT
IT
EL
PL
RU
EN
KZ