Self-Test; Operation; Charging The Rechargeable Battery; Trickle Charge - Mafell APS 18 M+ Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14

5.1 Self-test

Plug in the mains plug.
The warning display (4) and the operating mode
display (3) will light up in succession for approx.
1 second; the built-in fan will run for approx. 5
seconds.
6

Operation

6.1 Charging the rechargeable battery

Push the rechargeable battery pack
completely onto the sliding seat up
to the limit stop (2).
The operating mode display (3) is
blinking.
To display the charging state of a li-
ion rechargeable battery pack 18 V,
remove the rechargeable battery
pack from the charger and then
press the button on the
rechargeable battery pack.
8

Troubleshooting

Some of the most frequent defects and their causes are listed in the following chart. In case of other defects,
contact your dealer or the MAFELL customer service.
Defect
The warning display (4) lights up
constantly
The warning display (4) is blinking
Danger
Determining the causes for existing defects and eliminating these always
requires increased attention and caution. Pull the mains plug beforehand!
Cause
The rechargeable battery pack is
not charged, temperature too
high/too low
Rechargeable battery defective
The rechargeable battery pack
has not been pushed correctly
onto the sliding seat (2).
-13-

6.2 Trickle charge

Once charging is complete, the
charger switches automatically to
trickle charge. The rechargeable
battery pack can remain inside the
charger and is thus always ready
for operation. The operating mode
display (3) lights up constantly.
7

Service and maintenance

Danger
Pull the power plug during all
service work.
Always keep the device in a clean condition.
Should the device fail despite thorough manufacturing
and testing procedures, the repair must be carried out
by an authorised customer service station for
MAFELL electrical tools.
If the supply cable is damaged, it must be replaced by
a MAFELL customer service station because special
tools are required to do so.
Danger
Only use MAFELL accessories and
spare parts. Have components, the
replacement of which has not been
described, replaced at a MAFELL
customer service station.
Elimination
If the rechargeable battery pack
temperature ranges between 0 °C
and 50 °C, the charging operation
starts automatically.
Immediately remove the
rechargeable battery pack from the
charger.
Push rechargeable battery pack on
correctly.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aps 18 m

Table des Matières