SPECIFICATIONS

Display
Sensing
Polarity
Update rate
Operating
temperature
Relative
humidity
Storage
temperature
Measuring
category
Pollution
degree
Operating
altitude
Temperature
coefficient
Transient
Protection
Overload
protections
E.M.C.
Agency
approval
Power supply
Power
consumption
Low battery
indication
Auto power
OFF
Auto power
OFF power
consumption
Dimension
(L x W x H)
Weight
Jaw opening
& conductor
diameter
3-5/6 digits 6000 counts; dual display
True RMS
Automatic
5 per second nominal
32 °F to 104 °F (0 °C to 40 °C)
Maximum relative humidity 80% for temperature up to
31°C, decreasing linearly to 50% relative humidity at 40 °C
-4 °F to 140 °F (-20 °C to 60 °C), < 80% R.H. (with battery
removed)
CAT III 600 V
2
≤ 2000 m
nominal 0.15 x (specified accuracy)/
28
C to 40
C), or otherwise specified
O
O
6.0 kV (1.2/50 μs surge)
Current via jaws: 600 A AC rms continuous
V and COM terminals: 600 V AC/DC rms
Meets EN61326-1:2013
Temperature function at 80MHz ~ 150MHz, in an RF field
of 1V/m: Total Accuracy = Specified Accuracy + 25 digits
Other functions, in an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 20 digits
P
Two 1.5V AAA size battery
6.2mA typical (backlight OFF), 62mA typical (backlight ON)
Approx. 2.85 V for Capacitance & Hz; approx. 2.5 V for
other functions
Idle for 32 minutes (approx.)
5μA typical
8.62 x 3.03 x 1.46 in (219 x 77 x 37 mm)
208 g (0.46 lb) with batteries installed
1.18 in (30 mm)
O