8. Decommissioning

If operation is to be terminated, proceed as follows:
• Disconnect the dirt water pump from the power supply, pull the mains plug from the mains socket.
• Pull the dirt water pump from the water using the carry handle.
The dirt water pump must never be pulled out by the mains cable! This damages the mains cable; there
is danger to life from electric shock!
Pulling out the dirt water pump via the hose is impermissible as well. It may come loose when being pulled
out, which causes the dirt water pump to drop down and be damaged.
• Disconnect the hose from the dirt water pump.
• Let residual water run out of the dirt water pump by holding it diagonally. Any present contamination residue may
be flushed out with clear water (e.g. via a garden hose); disassemble the L-shaped hose adapter first if required.
• Dry the dirt water pump and the mains cable. Coil up the mains cable.
• Store the dirt water pump in a frost-protected and dry room over winter.
• After operation or emptying, a small amount of water may remain in the dirt water pump. Therefore, use a suitable
support when storing or transporting it in a vehicle.

9. Maintenance and Cleaning

The dirt water pump has no parts that require maintenance by you. Therefore, never open or disassemble it.
Maintenance or repair and opening of the dirt water pump in this context must only be performed by a specialist or
specialist workshop. Only use genuine spare parts.
Before cleaning, disconnect the dirt water pump from the mains voltage; pull the mains plug from the mains socket.
Use suitable protective clothing if required to prevent danger to health when handling the contaminated conveyed
liquid or dirt water pump.
To clean the outside of the dirt water pump, a dry, soft and clean cloth is sufficient. If required, flush the outside with
clear, clean water.
Any contamination of intake openings or the suction basket may be removed under running water (e.g. garden hose).
The pump inside may be flushed with running water as well by removing the L-shaped hose adapter first.
Dry the dirt water pump and the mains cable before storing it.
Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions for cleaning, since
these may damage the casing or even impair function.