Technical Data - Calira DC-Matic Mode D'emploi

Convertisseur up-down 12 volt / 24 volt
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

%

Technical data

Input voltage:
Forward mode 21.5 - 28.8 V direct voltage
Reverse mode 13 - 14.4 V direct voltage
Output voltage:
Forward mode 14.4 V direct voltage (at 20° C)
Reverse mode 27.6 V direct voltage
Output current:
Forward mode 35 A
Reverse mode 4 A
Temperature-
The values of the automatic switching refer to a battery
dependent control,
temperature of 20° C. When using a temperature sensor at
forward mode:
the battery, these values vary as a function of the battery
(optional)
temperature.
High temperature => Lower threshold values.
Low temperature => higher threshold values.
Charging process:
Automatic
Temperature:
Ambient temperature of -15° C to +35° C. During
operation, the housing may heat up to approx. 75 °C.
Cooling:
Through convection and an electric fan
Implementation:
According to Association of German Electrotechnical
Engineers regulations and the provisions of the
Instrument Safety Act.
Test labelling:
Use:
Forward mode for charging of batteries with a rated
voltage of 12 volts and a capacity of 160Ah-400Ah.
Reverse mode for charging of batteries with a rated
voltage of 24 volts and a capacity of > 100Ah.
!
" #
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49(0)8341 / 9764-0 Fax: +49(0)8341 / 67806
$