Vogel IG502-E Instructions De Service page 60

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 83
Display
Meaning
Explanation
Fault: Low Level The minimum level in the reser-
voir has been reached
Fault: Cycle
No signal from the cycle switch is
Switch
received during the pump
running time
Fault: Pressure
No signal from the pressure
Switch
switch is received during the
pump running time
Operation
The values subsequently displayed are the operation hours of the
Hour Meter
control unit.
Fault
The values subsequently displayed is the time in hours for which the
Hour Meter
control unit has been operated in the FAULT state.
Block operation
No signal is received from the cycle switch. The control unit is still in
the monitoring mode instead of the normal mode of operation. If the
fault continues to be active through 3 pump running times, a fault
message is displayed.
Page 17
Contents
Chapter
5
Operating Instruction Universal Control Unit IG502-E
Control funktion
The control unit is in the
FAULT state.
The execution of functions is
disabled.
The control unit is in the
FAULT state.
The execution of functions is
disabled.
The control unit is in the
FAULT state.
The execution of functions is
disabled.
Central
Lubrication

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Vogel IG502-E