Technical data
T2Blue
Nominal voltage
Nominal power
Min. bending radius
Min. cable spacing
Max. exposure temp.
Min. installation temp.
Length of cold lead cable
Approvals
Below listed floor covering materials can be used with lowest
thermal conductivity:
Tiles/marble/granite
Laying in screed (30-50 mm)
A
1. Tile floor covering (tiles or natural stone)
2. Adhesive
3. Watertight layer (optional for wet areas)
4. Special screed for underfloor heating systems (30 – 50 mm)
5. T2Blue heating cable
6. Metal/mesh
7. Plastic foil
8. High density polystyrene insulation (thickness 30 – 50 mm)
9. Subfloor construction (concrete, tiles, wood, PVC, ...) without thermal
insulation
Laying in self leveling compound (15-30 mm)
B
1. Tile floor covering (tiles or natural stone)
2. Tile adhesive
3. Watertight layer (optional for wet areas)
4. Special (self-levelling) mortar for underfloor heating systems
(≥ 15 mm)
5. T2Blue 10 W/m
6. Metal/mesh (optional only needed for wooden combustable subfloors)
7. Existing floor (tiles, wood, PVC, ...) with thermal insulation
T2Blue-10
T2Blue-20
max. thickness 30 mm
AC 230 V
10 W/m
20 W/m
30 mm
50 mm
+90°C
+5°C
2,5 m
VDE, SEMKO,
λ = 1,0 W/mK