Trilux LMS RGBW Mode D'emploi Et Instructions D'installation page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Standard connection diagram for the LMS RGBW Control Panel
for using single-channel ECGs
The DALI ECGs for the coloured light sources must be addressed beforehand with
an external tool and assigned to Dali groups. All other DALI parameters are
Program all DALI ECGs with red light sources to DALI group 0!
Program all DALI ECGs with green light sources to DALI group 1!
Program all DALI ECGs with blue light sources to DALI group 2!
Program all DALI ECGs with white light sources to DALI group 3!
N
L
PE
Relay contact can be optionally used (max. 1000W).
If several touch panels are used, these are simply switched in parallel
(+UB, GND, A, B parallel on all touch panels)
All ECGs with RGBW light sources
(max. 16 DALI loads)
programmed in the ECGs by the IRD400.
N
L
PE
1 (E2)
LMS WW DALI Interface
2 (E1)
3 (N)
(TOC 64 723 00)
4 (L)
5
16
DALI to ECGs
IRD400
DALI 2
9
(max 16)
10
DALI 1
11
(max 16)
12

Publicité

Table des Matières
loading

Table des Matières