Bradley S19-310DCFW Manuel D'installation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
Installation
NOTICE! Avoid cleaners containing organic
solvents, alcohols, and hydrocarbons.
Rinse with water after cleaning.
Supplies Required:
• (3) ³⁄₈" floor anchors and bolts
• Teflon tape and pipe sealant
• Piping to 1¼" NPT water supply inlet and 1¼"
NPT drain outlet on unit
• Adequate supply pipe supports
• Minimum 4" (102mm) drain to accommodate
30 gallons (115 liters) per minute discharge for
shower waste
• OPTIONAL: sign-mounting hardware
Local codes may require the installation of a backflow
prevention valve to complete proper installation.
Compliance with local codes is the responsibility of the
installer. Valve must be tested annually to verify that it
is functioning properly. Backflow prevention valves are
not included with the fixture and may be supplied by
the contractor or purchased from Bradley Corporation.
Step 1: Secure base to floor
1. Install three suitable anchors (supplied by installer) for ³⁄₈"
bolts in the floor.
2. Bolt the base to the floor anchors using ³⁄₈" bolts (supplied
by installer).
Step 2: Assemble components
1. Assemble the remaining unit components as shown on
page 4.
• Apply pipe sealant (by installer) to all male-
threaded pipe joints.
• Use the rubber grip pad provided or a strap
wrench around pipes when tightening to prevent
marring. Place the grip pad on the pipe, then put
the wrench over the grip pad and turn the pipe
with the wrench.
• Bottom edge of the showerhead should be 86"
(2184mm) from the floor.
Step 3: Connect water supply
IMPORTANT! Do not rely on Bradley's Combination
Unit to support supply piping.
1. Connect water supply piping to 1¼" NPT inlet on unit
(piping by installer). Provide adequate supports (by
installer) for supply pipe using pipe hangers or other
means.
2. Connect drain piping to 1¼" NPT drain outlet on unit
(piping by installer).
3. Hang the safety sign from the unit with the curtain hooks
provided (or mount it to the wall using sign-mounting
hardware by installer).
Bradley • 215-163DCFW Rev. N; ECN 12-05-003C
25³⁄₈"
(645mm)
4½"
(114mm)
Ø 3¹⁄₁₀"
(79mm)
(229mm)
86"
(2184mm)
to bottom
of base
68½"
(1740mm)
to bottom
of base
42"
(1067mm)
to bottom
of base
Top View From Bowl
Ø 10¾"
(273mm)
10½"
(267mm)
All dimensions assume standard thread
engagement. Variations in manufacturing
allow for +/- ¹⁄₈" (3mm) per threaded joint.
To find the tolerance of a dimension, add
the number of thread joints in between a
dimension and multiply it by ¹⁄₈" (3mm).
10/19/2012
S19-310DCFW
9"
(1676mm)
to bottom
of base
36³⁄₈"
(924mm)
to bottom
of base
6"
(152mm)
9½"
(241mm)
Ø 9" (229mm) Flange
with (3) Ø ³⁄₈" (10mm)
Holes on Ø 8"
(203mm) Bolt Circle
66"
3