3. Determine and mark centerline of the cutout space. The
mounting can be installed on either the left side or right side
of the cutout. Position mounting bracket against the wall in
the cutout so that the V-notch of the bracket is 9
from centerline as shown.
Centerline
A. 9
5
B. Bracket V-notch
4. Drill two 1/8" (3 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Rear position
Front position
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to
the wall or floor with the two #12 x 1
provided.
6. Move range close enough to opening to allow for final
gas and electrical connections. Remove shipping base,
cardboard, or hardboard from under range.
7. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
8. Move range forward onto shipping base, cardboard, or
hardboard to continue installing the range, using the
following installation instructions.
8
5
⁄
" (24.6 cm)
8
B
A
⁄
" (24.6 cm)
8
Diagonal (2 options)
5
⁄
" (4.1 cm) screws
8
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to Propane gas, have a qualified person
make sure gas pressure does not exceed 14" (36 cm)
water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with Propane Gas
to the smaller thread ends of the flexible connector adapters
(see B and F in the following illustration).
2. Attach 1 adapter to the gas pressure regulator and the other
adapter to the gas shut-off valve. Tighten both adapters,
being certain not to move or turn the gas pressure regulator.
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn when tightening
fittings.
A. Pressure regulator
connection fitting
B. Use pipe-joint compound.
C. Adapter
D. Flexible connector
A
B
D
C
F
E
G
H
E. Adapter
F. Use pipe-joint compound.
G. Manual shut-off valve
H. 1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe