indicator lamp to flash. Simply repeat the procedure if the selected channel or
function is not satisfactory.
Warning! The relevant relay is activated during the programming. This may
cause an inadvertent activation of some equipment.
Attaching the Lid
It is possible to fix the lid of the GL-1M model with the included screws.
Cleaning
Dip a rag into water with a little washing-up liquid in it and wring it out well.
This can then be used to clean the outer casing of the receiver.
Technical Specifications
Supply voltage:
Maximum current drawn when idle: 12 mA (2 detectors, relay inactive)
Maximum current drawn:
Maximum relay load:
Maximum number of detectors:
Programming channels:
Ambient temperature:
Surroundings:
"
Dimensions:
"
"
12-24 VAC/DC (-10% - +20%)
17 mA (2 detectors, relay active)
3A, 24 V AC/DC resistive load
2, including internal detector
GewaLink channels 0-127 (channel 62 is
without function) and one coded channel
(4096).
-20° - +35°C, (-4° - +95°F)
Indoors: GL-1M, GL-1M OEM (IP-21)
Outdoors: GL-1MU (IP-55)
GL-1M: 96 x 96 x 36 mm
GL-1M OEM 80 x 80 x 25 mm
(fits into equipment units with 60 mm c/c)
GL-1MU 82 x 95 x 57 mm
8