6.3
Programming sensors
In relation to the allocation of the switching states, wind sensors have a higher priority
than light sensors.
For the programming of sensors (sensor transmitters), the switching status (ON / OFF) can be
learnt in free allocation to UP / DOWN positioning commands of the BiRec On/Off.
1. Programming the switching status ON:
By single activation of the UP or DOWN button, define alerts during fast flashing of the
control lamp.
2. Programming the switching status OFF:
By single activation of the UP or DOWN button, define alerts during slow flashing of the
control lamp.
The programming procedure is completed.
If several sensors are programmed on the BiRec On/Off, the last sensor to be programmed
defines the allocation of all sensors within the sensor transmitter group.
6.4
Deleting the BiRec On/Off remote-receiver
To delete individual dispatchers from the
receiver
To delete all dispatchers from the receiver
(default setting)
Technical data
7
Operating voltage/
(Supply voltage)
Power consumption
Switching capacity
Radio frequency
Transmission capacity
Range
Permissible ambient temperature
Dimensions (L x W x H)
Weight
IP code
BiConnect BiRec On/ Off
Assembly and installation instructions/ Notice de montage et d'installation
We reserve the right to make technical changes/ Sous reserve de modifications techniques
Hold down the STOP key and LEARN key (1)
at the same time for approx. 10 sec.
Hold down the STOP key as well as the
LEARN key (1), UP and DOWN keys at the
same time for approx. 10 sec.
198 – 253 V/Hz / 50 – 60 V/Hz
< 0.5 (stand by) W
max. 2000 VA
868 MHz
10 mW
up to 100 m (free field)
approx. 30 m (in buildings)
0 – 55°C
110 x 60 x 40 mm (without plug connector)
200 g
IP 20
Version 1
2016-01-01
Item number/
Numéro d'article 119759-0000 Page 9/20