▶ When installing the appliance, check that
the power cable is not trapped or dam-
aged.
12.4 Information on the installation situation
¡ Install this appliance in a kitchen cupboard.
12.5 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ An exhaust air pipe that is made of non-combustible
material.
¡ To prevent condensate from returning, fit the ex-
haust air pipe from the appliance with a 1° gradient.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
12.6 Instructions for the electrical
connection
In order to be able to safely connect the appliance to
the electrical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
▶
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
▶
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
▶
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
▶
¡ The connection data can be found on the rating pla-
te inside the appliance.
¡ To see the rating plate, remove the grease filter.
¡ The connecting cable is approx. 1.30 m long.
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
Therefore, only use the appliance with a protective
earth connection.
¡ Do not connect the appliance to the power supply
during installation.
¡ Ensure that the protection against contact is guaran-
teed during installation.
12.7 General information
Follow these general instructions during the installation.
¡ For the installation, observe the currently valid buil-
ding regulations and the regulations of the local
electricity and gas suppliers.
¡ When discharging the exhaust air, the official and le-
gal regulations, such as the regional building code.,
must be observed.
¡ The width of the extractor hood must correspond at
least with the width of the hob.
¡ To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
¡ In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡ The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
12.8 Installation
Checking the unit
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The max. weight of the appliance is 18 kg.
Ensure that the fitted unit is heat-resistant up to
2.
90 °C.
Ensure that the fitted unit is still stable after the cut-
3.
outs have been made.
Ensure that the fitted unit complies with the following
4.
dimensions:
Width
Depth
Height
Preparing the units
Requirement: The unit is suitable for the installation.
→ "Checking the unit", Page 25
Cover the hob to prevent damage.
1.
Ensure that the stability of the fitted unit is guaran-
2.
teed after the cut-outs have been made.
If the cabinet is less than 320 mm deep, remove
3.
part of the back panel.
Installation instructions en
600 mm
Min. 320 mm
Min. 390 mm
25