ATTENTION: the operations for replacing the cassette must be carried out by an authorized person.
7.1
Procedure for replacing cassette
1. Remove the plug from the socket.
2. Disconnect the water supply.
3. Make sure that the drain hose is free and can move with the movement that is necessary to gain access
to the top.
4. Make sure that the water supply hose has sufficient room to move with it, or disconnect from the tap.
5. Undo the screws on the side of the brackets so that the Evap humidifier can be turned in the bracket.
Use a crosshead 2 or 3 screwdriver.
6. Turn the Evap humidifier 90° so that the cassette is accessible. Take into account any leakage water
from the side of the unit!
7. Disconnect the Evap cassette from the water supply by pushing in the ring of the knee joint (on side of
the housing) and sliding the whole knee off of the black hose. In this way the cassette is
disconnected and can be removed.
8. Pull/slide the cassette from the Evap humidifier, using the supplied tool (large plug).
9. Clean the inside of Evap with a soft cloth if necessary.
Do NOT use a cleaning product!
10. Remove the new Evap cassette from the packaging.
11. Push/slide this into the unit.
12. Push the black elbow coupling (on the Evap cassette) onto the black hose.
13. Turn the Evap humidifier so that it is sitting level.
14. Tighten the brackets.
15. Open the water supply duct
16. Insert the plug into the socket.
17. Your Evap humidifier is again safe, reliable and ready for a new period!
Specific actions are required when replacing the cassette. Should you have any doubts about how
to replace the cassette, we recommend that you contact your installer.
NB: The entire used Evap cassette,including the residual waste, may be disposed of.
¹ See chapter 10 for version adjustment
Section 7 – Maintenance
Press the
knee ring
Evap
Disconnecting
the hose
9