BECATRANS
3.3.2 Installation in an Existing Chimney
In all installation configurations the hearth plate must be made of non-
combustible materials.
If the chimney walls are made of combustible materials, the installation must be
done as described on page 11.
In the case of non-combustible materials, it is recommended that an air space be
left around the appliance.
1 - Possible tubing with vent when the
existing conduit is not compatible.
2 - Decompression holes to ventilate the
space between deflector and ceiling.
3 - Deflector to guide convection air.
4 - Flue flue made of bushels or insulated
metal ductwork.
5 - Warm air diffusion grille.
6 - Insulation.
7 - Hood.
8 - Insulation.
9 - Convection air intake.
10 - Base (or log) well leveled and ventilated
on stable and reinforced ground.
11 - Access hatch (500 x 350 mm) for access
to the connecting duct, draught moderator,
vacuum outlets, etc...
D - Safety distance at least 16 cm from the
inside wall of the pipe.
BECAFIRE