INSTALLING YOUR REFRIGERATOR
Do not remove
ground prong
Figure 3
Figure 4
Figure 5
Front grille
Front grille screw
5
WARNING
!
Electrical Shock Hazard
•
Do not use an extension cord with this ap-
pliance. They can be hazardous and can
degrade product performance.
•
This appliance should not, under any cir-
cumstances, be installed to an un-ground-
ed electrical supply.
•
Do not remove the grounding prong from
the power cord. (See Figure 3).
•
Do not use an adapter. (See Figure 4).
•
Do not splash or spray water from a hose
on the appliance. Doing so may cause
an electrical shock, which may result in
severe injury or death.
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is
required.
This product is factory equipped with a power
supply cord that has a three-pronged, grounded
plug. It must be plugged into a mating grounding
type receptacle in accordance with the National
Electrical Code and applicable local codes and or-
dinances (see Figure 6). If the circuit does not have
a grounding type receptacle, it is the responsibility
and obligation of the customer to provide the proper
power supply. The third ground prong should not,
under any circumstances, be cut or removed.
Figure 6
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone
to nuisance tripping which will cause the appliance
to shut down. GFCI's are generally not used on
circuits with power equipment that must run unat-
tended for long periods of time, unless required to
meet local building codes and ordinances.