Operation
5.2.1
Adding cleaning agents
If an additional cleaning agent is to be added if the surface is heavily soiled, a suction hose must be connected
(see Fig. 5, 5b).
When mixing cleaning agents, the lance must be switched to low pressure!
Switching from high to low pressure
Lance - Flat jet nozzle (see arrow →)
5.2.2
Accessories: SSK Sandblasting Kit
For removal of stubborn dirt, rust removal and the like, blasting
sand can be added to the spray water (quartz sand with max.
grain size 0.1 - 0.5 mm).
Connect the sandblasting kit to the unit.
Start the unit (EC-60).
Wait until the pump has drawn water, then close the cross-flushing
(close/close), otherwise air will be drawn in via the cross-flushing.
51700004
Fig 6
Bild 7
Gun with lance (flat spray nozzle)
Exchange set lance with rotary
nozzle (cutter head)
Lance - Rotating nozzle (see arrow →)