Fitting the brushes

Featuring the Nulock brush system.
The brush is simply pushed and twisted to lock, making fitting and removal a simple process.
The Pad is retained using Numatic's own PadLoc system. (Ask your supplier for details)
Only use manufacturer supplied brushes / pads.
ETB 1120 requires a 20'' brush or pad
Safety gloves are recommended for the changing of used brushes.

Tipping the Brush Deck

Fitting and lowering the Floor Tool

The floor tool has been designed for quick fitting, allowing easy squeegee blade replacement.
Note:
It is easier to fit the floor-tool if the weight of the machine is resting on the brush. Ensure the brush is fitted first.
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
BEFORE MAKING ANY ADJUSTMENTS
Fit the brush /pad to the drive chuck,
twist to lock the brush
(Fig 14) / pad in place (Fig 15).
Fig 14
To tip the deck into the down position
(Operating mode) Press in the brush
deck locking bar (Fig 16) and rotate the
brush deck (Fig 17).
To change to brush deck up position,
(Transit mode) simply lift the deck and
the sprung loaded locking bar will active
Fig 16
to hold the deck up.
Fit the floor tool and retain using
the detent Pin (Fig 18).
The lifting strap is held by a
detent pin (Fig 19).
Raise the floor tool for transit or
Fig 18
lower for cleaning operation using
the lifting handle fitted to the back
of the machine (Fig 20).
We are now ready to set the
controls to suit the cleaning
conditions.
Before any settings can be
applied, ensure the brush deck is
lowered.
10

Machine Set-Up

Fig 15
!
Fig 17
Fig 19
Fig 20