Function Test And Maintenance - Tunze 7607/2 Mode D'emploi

Table des Matières

Publicité

Function test and maintenance

Function test
Carry out the function test by lifting the overflow
sensors and by pressing down the run-dry sensor.
The floats have to be checked individually. After
actuation of the individual sensors, the units
connected to the switched socket outlet have to be
switched off and an alert signal has to be sounded.
The alert signal is switched off and the switched
socket outlet is switched on again, by pressing the
"Reset" button (4) briefly.
When the sensor (2) is pressed down, the LED (1)
has to light up and the LED (5) has to go off.
Subsequently press the "Reset" button (4). By lifting
the sensors (7) and (9), the LEDs (6) and (8) are
activated correspondingly.
Maintenance
A function test of the Water Level Alarm has to
be carried out in intervals of four weeks. Please
observe the chapter titled "Servicing the sensors"
on the pages following.
Test des fonctions et entretien
Test des fonctions
Ce test s'effectue en remontant les flotteurs des
capteurs anti-débordement et en abaissant celui
du capteur contre la marche à sec. Les capteurs
doivent être testés individuellement.
Après action sur chaque capteur, les appareillages
reliés à la prise commandés doivent se retrouver hors
service avec signal sonore. L'effacement du défaut
ainsi que le ré-enclenchement des appareillages
s'effectue par une courte impulsion sur le bouton
«Reset» (4).
Une action sur le capteur (2) doit provoquer
l'allumage de la LED (1) et l'extinction de la LED (5),
effacez le défaut par «Reset» (4). De même, une
action sur les capteurs (7) et (9) provoque l'allumage
des LED (6) et (8).
Entretien
Un test complet des fonctions de Water Level Alarm
doit être entrepris toutes les 4 semaines. Veuillez
encore observer «Entretien des capteurs» dans les
pages suivantes.
45