Models:
SA-90DC3
SA-90DC3H
SA-90DC3HM
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the
exact service motor. The impeller should also be replaced.
OPERATION
See "Connect Wiring" for details.
The control box, located inside the fan housing, has three separate adjustments:
(1) The low airflow knob adjusts the lower airflow from 30 CFM up to the air flow rate of the high fan speed determined by the toggle switch setting.
The low airflow setting is de-activated when set between OFF-30CFM (factory set to OFF)
(2) For SA-90DC3 The time delay knob is adjustable from 3 to 30 minutes and will switch the fan to the low speed setting after the switch II is turned off
for the set period of time.
The time delay setting is de-activated when set between OFF-3 mins (factory set to OFF).
SA-90DC3H and SA-90DC3HM the humidity sensor knob set user-adjustable setpoint.
The humidity sensor is de-activated when set between OFF-30% (factory set to 80%).
(3) The toggle switch will adjust the upper fan speed setting from 50 to 100 CFM (factory set to 100CFM).
For SA-90DC3
Low
airflow
knob
50%
30CFM
OFF
S
Switch position
Airflow(CFM)
Duct diameter
To change the pre-selected airflow,adjust
the control switches as per the table above.
is the position of switch
Cod: 0060300000-A
Toggle
switch
Time
delay
1
2
knob
12
70%
21
3
30
OFF
Max.
T(min)
1 2
1 2
1 2
50
80
100
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
For SA-90DC3H SA-90DC3HM
Low
airflow
knob
Control
box
30CFM
OFF
Switch position
Airflow(CFM)
Duct diameter
To change the pre-selected airflow,adjust
the control switches as per the table above.
is the position of switch
VENTILATION FAN
Toggle
switch
1
2
50%
45
70%
60
30
80
OFF
Max.
S
H(%)
1 2
1 2
50
80
Humidity
sensor
knob
Control
box
1 2
100

Publicité

loading

Sommaire des Matières pour Air Specialties Softaire SA-90DC3

  • Page 1 VENTILATION FAN b y A i r S p e c i a l i t i e s Models: SA-90DC3 SA-90DC3H SA-90DC3HM WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 2 OPERATION To Turn Fan ON For SA-90DC3H SA-90DC3HM Turn the switch I (according to the following “CONNECT ELECTRICAL SENSITIVITY ADJUSTMENT WIRING” ) ON. The “H” has been factory set for most shower applications. However, if • Fan will run at the certified airflow rate if the switch II is ON. the fan is in a tub area or is being used for dampness control, the “H”...
  • Page 3 ASSEMBLY INSTRUCTIONS 2. Mount with mountion holes and hanger bar a. Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing. b. Hold housing in place so that the housing contact the bottom of the joist, Screw housing to joist through the hole of the housing .
  • Page 4 CONNECT ELECTRICAL WIRING Run 120 VAC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. BLACK (BLK) WHITE (WHT) GROUND (GRD)
  • Page 5 VENTILATEUR b y A i r S p e c i a l i t i e s Models: SA-90DC3 SA-90DC3H SA-90DC3HM AVERTISSEMENT 1. Utilisez cet appareil uniquement de la manière prévue par le fabricant. Si vous avez des questions, contactez le fabricant à l'adresse ou au numéro de téléphone figurant dans la garantie.
  • Page 6 FONCTIONNEMENT Pour activer le ventilateur RÉGLAGE DE SENSIBILITÉ Allumez l’interrupteur I (conformément au paragraphe « RACCORDEMENT Le « H » a été réglé en usine pour la plupart des applications de douche. Cependant, si le ÉLECTRIQUE»). ventilateur est dans une salle avec baignoire ou est utilisé pour le contrôle de l'humidité, •...
  • Page 7 INSTRUCTIONS 2. Fixer avec les trous de fixation et la barre de suspension a. Faites glisser une barre de suspension dans le canal du boîtier et ajustez-la selon les besoins pour la fixer entre les cadres. b. Maintenir le boîtier en place de sorte que celui-ci touche le bas de la solive. Visser le boîtier à...
  • Page 8 BRANCHEMENT DES FILS ÉLECTRIQUES Relier le circuit électrique de votre maison de 120 V c.a. à l’emplacement du ventilateur. Utilisez seulement des raccords homologués par UL pour relier le circuit électrique de votre maison à la plaque de câblage. Branchez les fils comme illustré ci-dessous. NOIR (BLK) BLANC (WHT) BRUN (BRN)

Ce manuel est également adapté pour:

Softaire sa-90dc3hSoftaire sa-90dc3hm