APPLICATION :
 This submersible sump pump is designed
for a permanent sump installation.
 For dewatering around homes and farms.
It can be used in light commercial application.
CAPACITY :
5' 3000 US GPH
10' 2500 US GPH
15' 2000 US GPH
18' 1450 US GPH
IMPORTANT NOTICE
The following are minimum requirements in order to protect your residence from flooding. It
is a small investment but it is your personal responsibility to protect your home, family and
valuables. Failure to comply with the following requirements may also void your warranty :
• Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and
the second pump as the backup unit.
• Burcam alarm system model 450455 has to be installed to advise you any malfunctions.
• As sump pumps are electrically powered and activated so to prevent flooding, a Burcam
battery powered back-up pump model 300403 has to be installed to evacuate the water.
Pump selection, proper and adequate installation are a must to comply with local by-laws and
need to be adhered to.
We recommend that you install your pump in a clean location where there is
STEP 1
adequate room for servicing at a later date. Protection from freezing
temperatures and good ventilation should be considered as well, to provide
the pump an environment for long life. Do not use to pump gas or toxic
fuels. This submersible sump pump is designed to pump water only.
Friction losses in the discharge pipe must be taken into consideration when
the horizontal offset is greater than 50 feet. The discharge pipe should be
increased from 1 1/2" to 2". This will reduce friction losses and allow the
pump to give maximum performance.
More friction losses must also be taken into consideration when many
elbows and fittings are installed in the discharge line. Each elbows and
fittings must be considered as 1 feet of head.
The float switch of your pump has been pre-set at the factory and does not
need any adjustment.
Never run the pump dry. Damage to the seal may occur. Fill pump pit or
sump basin with water before turning on the power.
Assuming that you have a sump pit located in your basement floor. Your
STEP 2
sump pit must be constructed from concrete, brick, tile or more recently a
sump basin made from plastic and/or fiberglass. The minimum size of your
sump pit must be 18" in diameter and no less than 25" deep. When pit is
ready, proceed to next step.
Friction loss
in pipe not
included.
INSTRUCTION STEPS
Please note before you proceed with the installation of this
product that the manufacturer's guideline has to be respected.
Failure to comply may void your warranty.
FEATURES :
 Non-corrosive material.
 Stainless steel mechanical rotary seal.
 Thermal and overload protection.
 Grounded electric cable.
 1/3 HP, 115V AC, 60Hz, 4A, (9.5A when start).