Pin assignment of the DMX connection: Pin1 = earth / Pin2 = (-) / Pin3 = (+).
b) Setting up a Master-Slave Chain
The effect light can be operated controlled by a DMX controller or in a master-slave chain. In that case, the
integrated controller of the master device controls the connected slave devices.
• Connect the OUTPUT port of the master device to the INPUT port of the first slave device.
• Connect the OUTPUT port of the first slave device to the INPUT port of the next slave device.
• Proceed as described above with all remaining slave devices.
• Plug an XLR plug with a terminating resistor into the OUTPUT connection of the last slave device (as
described in section „Connection of a DMX controller").
10. Mains Connection
The mains socket to which the effect light is connected must be close to the device and easily
accessible to quickly separate the device from the mains voltage in case of an error.
Do not let the mains cable come into contact with other cables.
Be careful when handling mains cables and mains connections. Mains voltage may cause po-
tentially fatal electric shock.
Make sure that no cables are lying around openly. Install cables professionally to prevent acci-
dents.
Before plugging in the mains plug, ensure that the device voltage indicated at the effect light
corresponds to the available mains voltage. Do not connect the device if the indication does
not correspond to the available mains voltage. Incorrect supply voltage may lead to irreparable
damage to the device and danger to the user.
• Connect the low-voltage connector of the mains cable to the mains socket of the device.
• Plug the mains plug of the mains line into a grounded socket.
• Once the device has been connected to the mains voltage, it performs a reset and takes up operation
again.
28