Maintenance
• Save all instructions
Performing Maintenance:
Before performing maintenance, the Log Splitter must be placed in maintenance mode. Disconnect from
electrical power source and move the control lever forward and backwards to relieve the hydraulic pressure
before performing any maintenance, make sure all guards, shields and safety features are put back in place
before operating the Log Splitter.
Periodically check all fasteners for tightness and leaks.
Annually clean and lightly lubricate all moving parts or when needed.
Use a glossy enamel spray paint to touch up scratched or worn painted metal surfaces.
What
Hydraulic fluid
Each use
Nuts and bolts
Each use
Beam
Each use
Moving parts
Each use
NOTICE
If a part needs replacement, only use GENUINE parts that meet the manufacturer's specifications.
Replacement parts that do not meet specifications may result in a safety hazard or poor operations.
CAUTION
Always wear safety glasses with side shields or goggles marked to comply with ANSI Z87.1 prior to
performing maintenance.
Wear nitrile gloves prior to performing maintenance involving hydraulic oil.
When performing maintenance, if it is necessary to lift the unit, use two adults.
Replacing Hydraulic Oil:
NOTE: Replace the hydraulic oil in the Log Splitter after every 150 hours of use. Take following steps to replace it.
1. Make sure the Log Splitter is unplugged.
2. Unscrew oil drain bolt with dipstick to remove it.
3. Turn the Log Splitter on the support leg side over a
container to drain the hydraulic oil.
4. Lift the Log Splitter by the motor end.
5. Refill with hydraulic oil with 3.7 liters (118 oz) and
use type defined in the specifications table on
page 6.
6. Clean the surface of dipstick on the oil drain bolt and put it back into the oil tank while keeping the Log Splitter
vertically.
7. Make sure the level of the refilled oil is just between the two grooves around the dipstick.
8. Clean the oil drain bolt before replacing it. Make sure they are tightened to avoid leakage before placing the
Log Splitter horizontally.
NOTE: Periodically check the oil level and fill as necessary to ensure it is between the two grooves around
the dipstick.
NOTE: See recommended hydraulic oil types on page 6 under "Specification" section.
Questions? Call Toll Free at 1-800-737-2112
When
Check fluid level and add as required.
Check for loose bolts, tighten before operating.
Check for debris and freedom of movement.
Clear debris from Log Splitter.
Method
EN - 10
Copyright © 2018 MAT Engine Technologies, LLC