Position the loop on the horizontal counter-
2.
top by positionning the cable closest to the
customer.
Install the loop on the vertical countertop by
3.
positioning the cable closest to the customer.
Set the loop using the binding clips supplied for this purpose. For better durability, it may be ap-
propriate to install the loop in a plastic chute.
Then connect the connecting cable to the termi- nal block "amplifier" of the connector on the
terminal block "loop" of the amplifier.
Screw the connector on the cross.
For greater coverage around the counter, it is possible to install a cable on the floor. The loop can
be placed in the slab (over the wire mesh), under a coating (parquet, carpet, ... etc) using a
copper tape or glued under a carpet as shown in figure 3 .
The wire supplied in the DCL20-K kit produces a
magnetic field radiating on a perimeter of 1.2m
which allows a people to receive the signal
com- fortably.
The pictogram with an integrated loop can be
fixed on the desk and turned to the customer's
side to avoid disturbances due to metal (see
Figure 4).
Loop
amplifier
Figure4.
Loop1
Loop2
Attention, warning, danger:
The loop must not be positioned
under a metal structure. The ma-
gnetic field would be absorbed by the
metal mass and would not equip
the counter properly. There are
other solutions for installing a loop in a metal
counter (see figure 3)
Loop
amplifier
Figure 2.
amplifier
Figure3.
12