3. Connecting electrical wiring
WARNING: Ensure main power is off.
•
Connect house wires to ventilation fan wires.
•
Match colours as shown (black to black, white to white, and green
to green) using wire connectors (not provided).
•
Replace the junction box cover. Do not pinch lead wires.
CAUTION: If your house wires do not match these colours,
determine what each wire represents before connecting.
You may need to consult a licensed electrician to determine
this safely.
WARNING: Failure to wire product correctly could result
in electrical shock, fire hazards, or damage to the product.
Consult a licensed electrician if you are unsure of your ability
to correctly install wiring.
Automatic
Terminal
Capacitator
Motor
5. Installing fan grill
•
Insert the mounting springs (B) into the screen (C).
•
Squeeze mounting springs together, and insert into main body.
5
Junction
box
(Black) to switch
(White) to neutral
(Green) to ground
4. Connecting duct work
•
Install a circular duct to outlet and secure it with duct tape or clamps.
•
Install duct work in a straight line with minimal bends.
•
Fan must be ventilated to the exterior.