Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due to
rough handling. Carefully inspect your pump
for damages that could cause failures. Report any
damage to your carrier or your point of purchase.
NOTICE
This unit has been designed to
pump water only. This unit is
not designed for applications
involving salt water, brine or any
other liquids including petroleum
products. Use with salt, brine
or any other liquids including
petroleum products will void the
warranty.
ELECTRICAL CONNECTION
For pumping systems using more
than one pump, each pump
needs to be connected to its own
dedicated circuit protected by a
fuse or breaker. The use of dedicated
circuits will allow the other pumps
to continue functioning even if
the fuse or breaker of one of the
pumps trips .
Tel. : 514.337.4415
Fax : 514.337.4029
info@burcam.com
www.burcam.com
INSTALLATION
INSTRUCTIONS
SUBMERSIBLE
SUMP PUMP
Please read these
carefully. Failure
© 2024 BURCAM Printed in Canada 311547
MODEL
300818Z
instructions
to comply to
instructions and
designed
operation of
this system,
may void
the warranty.

Publicité

loading

Sommaire des Matières pour Burcam 300818Z

  • Page 1 The use of dedicated circuits will allow the other pumps to continue functioning even if the fuse or breaker of one of the pumps trips . © 2024 BURCAM Printed in Canada 311547...
  • Page 2 SAFETY INSTRUCTIONS This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures : Check with your local electrical and plumbing codes to ensure you comply with the regulations.
  • Page 3 • Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump as the backup unit. • Burcam alarm system model 450455 has to be installed to advise you any malfunctions. • As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back-up pump model 300403 has to be installed to evacuate the water.
  • Page 4 SUMP PUMP APPLICATION (SEE DIAGRAM ON PAGE 5) At this step, you have the opportunity to install a 1 1/2” or a 1 1/4” discharge. STEP 3 We recommend a 1 1/2” ABS/DWV discharge. Install a check valve (350362 in-line 1 1/2” or 350353 1 1/4” MNPT inlet and 1 1/4” or 1 1/2” outlet or 350363 1 1/2’’...
  • Page 5 Pump body ‘‘O’’ ring 311540 Pump body 311541 Motor assembly 311542 Brass insert 311543 Impeller 311544 1 1/4’’ discharge adaptor 311545 Oil seal #1 311546 Oil seal #2 Repair parts may be ordered your authorized point of sale of from BURCAM PUMPS...
  • Page 6 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Switch is off position Turn switch to on position Motor does not run.
  • Page 7 à des fusibles ou disjoncteurs indépendants. Ainsi, l’alimentation électrique d’une pompe ne sera pas interrompu si le fusible de l’autre pompe brûle ou si le disjoncteur de l’autre pompe se déclenche. © 2024 BURCAM Imprimé au Canada 311547...
  • Page 8 CONSEILS DE SÉCURITÉ : La pompe que vous venez d’acquérir est un produit fabriqué avec les meilleurs matériaux et par une main-d’oeuvre spécialisée. Veuillez suivre les instructions d’utilisation et prendre les précautions nécessaires pour votre sécurité : Consultez les normes de plomberie et d’électricité se rapportant à...
  • Page 9 • Comme les pompes de puisard fonctionnent à l’électricité, pour prévenir une inondation, une pompe d’urgence à batterie Burcam modèle 300403 doit être installée pour évacuer l’eau. La sélection de pompe et l’installation adéquate et conforme sont obligatoires pour respecter les règles et codes locaux.
  • Page 10 APPLICATION DE POMPE PUISARD (VOIR LE DIAGRAMME À LA PAGE 5) Maintenant, vous avez la possibilité d’utiliser un tuyau de décharge de 1 1/2” ou ÉTAPE 3 de 1 1/4”. Nous recommandons une décharge de 1 1/2” ABS / DWV. Installer un clapet de retenue (350362 en ligne 1 1/2”...
  • Page 11 Moteur assemblé 311542 Insertion en laiton 311543 Impulseur 311544 Adaptateur de décharge de 1 1/4’’ 311545 Sceau d’huile #1 311546 Sceau d’huile #2 Les pièces de rechange peuvent être commandées de votre point de vente autorisé ou de POMPES BURCAM...
  • Page 12 GUIDE DE RÉSOLUTION DES PROBLÈMES LORS D’AJUSTEMENT SUR DES APPAREILS ÉLECTRIQUES, TOUJOURS S’ASSURER QUE LE COURANT EST DÉBRANCHÉ. NE PAS SEULEMENT ENLEVER LE FUSIBLE OU METTRE LE DISJONCTEUR HORS TENSION. IL FAUT DÉBRANCHER LE CÂBLE D’ALIMENTATION DE LA PRISE. PROBLÈME CAUSE POSSIBLE ACTION Commutateur hors circuit Remttre en circuit...