Electric Features; Mechanical Dimensions - Western Co SPC07-IP Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Road flashing indicator - alternated flash *:
Alternating lighting loads with a flash of 20ms for each second. From twilight ("light sensor" by the
panel)and for the whole period of darkness, the power supplied to loads is reduced.
WARNING: The configurations in the table are valid for controllers with software versions 2.5 (see image in the previous page to
*
understand the version of your SPC07IP).
Recharge connection
Temperature sensor
connect only if battery distance is
grater then 3 meter.
+LoadA
-LoadA
AuxIR
+LoadB
-LoadB

Electric Features:

FEATURES
Power supply Pb Battery ;
Panels voltage
Panels current
Low-battery voltage threshold
Voltage threshold end low battery
Total current load
Peak current load
End recharge voltage
Temperature coefficent for recharge voltage
Volt treshold on pannel for twilight ON
Volt treshold on pannel for twilight OFF
Working environment temperature
Section of power conductors
Weight

Mechanical dimensions:

Gnd
Text
Gnd
Sens
+Pan
-Pan
+Batt
-Batt
-
SPC07-IP
SYM CONDITION
Working voltage
V
12V
DD
Working current
I
no load, no panels, VDD=13V
DD
I
no load, no panel, discharged battery VDD=12V
DLB
no load, no panels, discharged battery VDD=10V
V
PAN
I
T=25°C
PAN
V
Voltage present for at least 5sec. 30% of discharge
LB
Voltage present for at least 5sec. 70% of discharge
V
Temperature 25°C
ELB
V
Continuous power supply
LD
V
max. time 120ms.; Tcase=25°C
PL
V
Battery temperature 25°C ±2°C
ECH
VTadj T
BATT
VTD
VTL
T
A
-
128
PG9
PG9
SPC07-IP
User manual
After having connected battery and module as you can see in the
+
scheme on the left side, verify that the signaling green LED in ON when
the PV module is exposed to sunlight; this shows that the PV module is
supplying current to the battery.
-
Terminals description:
+Pan / -Pan
+Batt / -Batt
+
+LoadA / -LoadA
+LoadB / -LoadB
12V
Text
Sens
AuxIR
>=-8°C<=60°C
PG9
PG9
tel: (+39) 0735 751248 fax: (+39) 0735 751254
4
PV module input
Battery input
Load A output
Load B output
Temperature sensor input (optional)
Input of IR command / remote load
Auxiliary output - 12V Max 100mA power
supplying IR sensor
MIN
TIP
MAX
5
12
15
6
6.3
6,5
4,5
5
5,5
5
5,2
5,4
0
17,2
22
0
7
10
<11,9
<12
<12,1
<10,9
<11
<11,1
>13,7
>13,8
>13,9
0
6
-
-
70
13,8
14,1
14,4
-
-20
<3,2
<3,4
<3,6
>6,5
>6,7
>6,9
-10
-
60
-
2,5
-
300
59
WESTERN CO. Srl
63074 San Benedetto del Tronto (AP)
e-mail:
info@western.it
web:
www.western.it
EN
UNIT
V
mA
mA
mA
V
A
V
V
V
7
A
A
V
-
mV/°C
V
V
°C
-
mm
2
-
g
Via Pasubio, 1

Publicité

Table des Matières
loading

Table des Matières