17. ELECTRICAL WIRING
• Connect the control unit(s) according to electrical scheme
• Electrical control scheme
Fail Open
module
6 5
4
3
2
1
10 11 12
15
18
7 8 9
L1
N
PE
Connection to counter-module.
Trigger with external NO dry contact relay.
Connect to "L" for CW-module.
DO NOT APPLY VOLTAGE HERE
Connect to "R" for CCW-module.
Min. requirements:
U: 30V DC
I: 0,2A
Min. impulse length: 30 ms
Max. impulse length: 1s
Turnitec (electro)mechanical control module
U max = 250V AC/30V DC
Imax = 2A (resistive)/1A (inductive)
Fail Close
CW
module
lights
NO
C
NC
20
21 22 23 24 25 26 27 28 29
10L 11L
12L
1 2 3 4 5 6 7
1 10V/230V AC*
50/60Hz
CW
CCW
counter
1 10V/230V AC*
(0.5s)
Fail Open
CCW
module
lights
NO
C
NC
10R
11R
12R
10 11 12
L1
N
PE
50/60Hz
U max = 250V AC/30V DC
Imax = 2A (resistive)/1A (inductive)
Fail Close
module
6
5 4
3
2
1
15
18
7 8 9
1 10V/230V AC*
50/60Hz
L1
N
PE
Trigger with external NO dry
contact relay.
DO NOT APPLY VOLTAGE HERE
Min. requirements:
U: 30V DC
I: 0.2A
Min. impulse length: 30 ms
Max. impulse length: 1s
Connection to counter-module.
Connect to "L" for CW-module.
Connect to "R" for CCW-module.
*1 10V units are provided for the US market